A Longitudinal Study of Sick Building Syndrome (SBS) among Pupils in Relation to SO2, NO2, O3 and PM10 in Schools in China

  • Xin Zhang,

    Affiliation Institute of Environmental Science, Shanxi University, Taiyuan, China

  • Fan Li,

    Affiliation Institute of Environmental Science, Shanxi University, Taiyuan, China

  • Li Zhang,

    Affiliation Institute of Environmental Science, Shanxi University, Taiyuan, China

  • Zhuohui Zhao ,

    zhzhao@fudan.edu.cn

    Affiliation School of Public Health, Fudan University, Shanghai, China

  • Dan Norback

    Affiliation Department of Medical Sciences, Occupational and Environmental Medicine, Uppsala University, Uppsala, Sweden

Abstract

There are fewer longitudinal studies from China on symptoms as described for the sick building syndrome (SBS). Here, we performed a two-year prospective study and investigated associations between environmental parameters such as room temperature, relative air humidity (RH), carbon dioxide (CO2), nitrogen dioxide (NO2), sulphur dioxide (SO2), ozone (O3), particulate matter (PM10), and health outcomes including prevalence, incidence and remission of SBS symptoms in junior high schools in Taiyuan, China. Totally 2134 pupils participated at baseline, and 1325 stayed in the same classrooms during the study period (2010–2012). The prevalence of mucosal symptoms, general symptoms and symptoms improved when away from school (school-related symptoms) was 22.7%, 20.4% and 39.2%, respectively, at baseline, and the prevalence increased during follow-up (P<0.001). At baseline, both indoor and outdoor SO2 were found positively associated with prevalence of school-related symptoms. Indoor O3 was shown to be positively associated with prevalence of skin symptoms. At follow-up, indoor PM10 was found to be positively associated with new onset of skin, mucosal and general symptoms. CO2 and RH were positively associated with new onset of mucosal, general and school-related symptoms. Outdoor SO2 was positively associated with new onset of skin symptoms, while outdoor NO2 was positively associated with new onset of skin, general and mucosal symptoms. Outdoor PM10 was found to be positively associated with new onset of skin, general and mucosal symptoms as well as school-related symptoms. In conclusion, symptoms as described for SBS were commonly found in school children in Taiyuan City, China, and increased during the two-year follow-up period. Environmental pollution, including PM10, SO2 and NO2, could increase the prevalence and incidence of SBS and decrease the remission rate. Moreover, parental asthma and allergy (heredity) and pollen or pet allergy (atopy) can be risk factors for SBS.

Introduction

Non-specific symptoms associated with the indoor climate problems, often called sick building syndrome (SBS), have been reported in Western countries since the 1970s. The symptoms include headaches, fatigue, and irritation in the upper airways nose, throat, eyes, hands and/or facial skin [1], [2]. The symptoms can be very common in particular buildings with indoor problems and the severity may vary from person to person, even within the same building [3]. Some studies restrict SBS to symptoms improved or disappearing when away from a particular indoor environment (transient symptoms) [4] while others include all symptoms, irrespectively if reported to be improved or not [5]. Researchers from North Europe have used the later definition for long time [6].

A number of personal, organisational and environmental factors can be associated with SBS. Indoor environmental factors associated with SBS include building dampness [7][9], low ventilation flow [10], volatile organic compounds (VOC) [11], mold and bacteria [12], microbial VOC (MVOC) [12] and room temperature [13][15]. Moreover, personal factors such as female gender, history of allergic disorders and perception of odor have been demonstrated to be associated with SBS [5], [16], [17].

Since children and adolescents are more vulnerable, the school environment has been suggested to be an important indoor environment in a public health perspective [18]. One study reported a high prevalence (25.2%) of SBS among primary school students in Japan [4], and another study reported 50% of SBS in one school in Sweden [19]. Most school environment studies have been performed in North America and Europe [20][22]. In Hong Kong, a number of environmental exposures were measured in five classrooms. The average respirable particulate matter concentrations were higher than the HK objective, and the maximum indoor PM10 level exceeded 1000 µg/m3. Indoor CO2 concentrations often exceeded 1000 ppm, indicating inadequate ventilation. It was concluded that the two most important classroom air quality problems were PM10 and CO2 levels [23]. Another epidemiological study in schools in Malaysia, measuring fungal DNA, reported associations between certain microbial species (Aspergillus versicolor and Streptomyces sp) and respiratory symptoms in school children [24]. Moreover, associations between building dampness and mould in the classroom and SBS in school children have been reported in Japanese and Danish schools [4], [25].

China has the largest population in the world but there are fewer studies on risk factors for SBS symptoms in China. We have previously performed a two-year follow-up study from 2004–2006 on SBS among junior high school students in schools in Taiyuan, a coal-burning city in Northern China [26]. The study demonstrated that NO2 and SO2 levels in the classrooms were positively associated with the prevalence of SBS symptoms. Moreover, parental asthma and allergy (heredity) and pollen or pet allergy (atopy) were risk factors for both prevalence and incidence of SBS [26]. In order to further study associations between SBS and indoor and outdoor air pollution in schools, including particulate matter (PM10), we have performed a new two-year longitudinal school environment study six years later in the same schools. Since the first study was performed the air pollution situation in Taiyuan city has been improved.

The aim was to investigate associations between measured indoor and outdoor environment and prevalence, new onset (incidence) and remission of SBS symptoms among junior high school students in schools in Taiyuan city, Shanxi province, China. The indoor climate measurements included room temperature, relative air humidity (RH) and concentration of carbon dioxide (CO2). The measured indoor and outdoor air pollutants included nitrogen dioxide (NO2), sulphur dioxide (SO2), ozone (O3) and particulate matter (PM10). Finally, we studied associations between gender, parental asthma or allergy (heredity), and pollen or pet allergen (atopy) and prevalence, incidence and remission of SBS symptoms. The study included symptoms improved when away from the school (school-related symptom) as well as total prevalence, incidence and remission of symptoms.

Materials and Methods

The study is a two-year follow-up of a cohort with repeated questionnaires in a random sample of Chinese pupils, at baseline and at follow-up, with environmental measurements at baseline.

Study design

Ten junior high schools were randomly selected in the urban area of Taiyuan, a city with three million inhabitants. Taiyuan is the capital of Shanxi province and is located 500 km south west of Beijing. Taiyuan is one of the most heavily polluted cities in China, and Shanxi province is a major coal mining area in China. All headmasters of the selected schools agreed to participate. Data on SBS symptoms were collected by questionnaires distributed to each student in randomly selected classes by the head teacher. The study was performed in March 2010 (baseline) and was repeated two years later at follow-up (March 2012). Measured air pollutants included nitrogen dioxide (NO2), sulphur dioxide (SO2), ozone (O3), particulate matter (PM10) and measured climate factors included temperature, RH and carbon dioxide (CO2). Environmental measurements were performed in each selected classroom and outside each school at baseline, only, during a two-week period in March 2010. The measurements were performed just after the questionnaire study was completed. The measurement period was in the end of the heating season in Taiyuan.

Study population

At baseline (2010), five first-year classes were randomly selected in each of the ten schools. If there were less than five first-year classes, all were selected. The study population consisted of 2335 pupils (11–15 years of age) in 44 classes, of which 2134 (91.4%) completed the questionnaire. There were no reports on health complaints or environmental problems from any of the schools before the investigation. At follow-up (2012), two schools that had been selected at baseline did not participate. In the end, 33 classes in eight schools completed the questionnaire. A total of 1325 pupils participated in both the initial study and follow-up. Air pollution and climate factors were measured in 32 classrooms with 1283 participants. Measurements could not be done in one classroom (with 42 participants) due to practical reason (lack of an electric outlet). All participating students stayed in the same classroom during lessons, except for sport, because each class had a fixed classroom during all three years of junior high school.

Ethics statement

There was informed consent from the pupils and the parents before the study. We gave the parents, the children, and their head teacher an information letter together with the questionnaire, stating that if they answered and returned the questionnaire it meant they had given informed consent. The nature and possible consequences of the study were explained before the study began. The questionnaire study and the exposure measurements in the schools had permission from the principal of each school and the head teacher of each class involved in the study. All personal information from questionnaire was kept confidential. The study protocol and the consent procedure were approved by the Institute of High School Student Health Care in Taiyuan which did not require a written consent since the study only included questionnaires and no clinical tests.

Questionnaire data

Students were given a self-administered questionnaire to collect data about age, sex, parental asthma or allergy (heredity), allergy, asthma, and medical symptoms compatible with SBS. Questions on allergy and respiratory health included ‘yes/no’ questions of doctor diagnosed asthma, current asthma and allergies to dog, cat or pollen. The questionnaire survey was performed one week before the classroom inspections and measurements. The questionnaires were distributed by the class teachers. The same questionnaire was used in 2010 and 2012. The questionnaire was based on previous school studies [8], [26]. SBS-symptoms included facial and hand rash or itching; eczema; eye irritation; swollen eyelids; nasal catarrh and obstruction; dryness in the throat; sore throat; irritating cough; headache; nausea; sensation of getting a cold and tiredness. The recall period was 3 months. Each question had four alternative answers: ‘Yes, everyday’; ‘Yes, 1–4 times/week’; ‘Yes, 1–3 times/month’; and ‘No, never’. In addition, a question concerning whether any of the SBS symptoms improved when they stayed away from school (school- related symptoms) was also included. In the statistical calculations, for mucosal (eye irritation, swollen eyelids, nasal catarrh, nasal obstruction, dryness in throat, sore throat or irritating cough), general (headache, nausea, sensation of getting a cold or tiredness) and dermal symptoms (facial and hand rash or itching, eczema), weekly symptom (yes everyday or days 1–4 times/week) was coded 1 and 1–3 times/month or never was coded 0. For symptoms improved when away from school, any symptoms improved were coded 1 and no symptoms improved when away from school was coded 0.

Building inspection and climate measurements

Details on building construction, materials, pot plants, number of students and type of ventilation system were noted, as were any sign of building dampness, such as damp spots, water leakage or indoor mould growth in the classrooms. Temperature (°C), relative air humidity (RH%) and CO2 (ppm) concentration were measured during normal activities in the classrooms using a Q-track IAQ monitor (TSI Incorporated, St. Paul, MN, USA). Corresponding Q-track measurements were done simultaneously outside each school.

Air pollution measurements

Indoor levels of SO2, NO2 and O3 were measured in the selected classrooms (N = 32) and outdoor levels were measured at one representative location in each school by diffusion samplers. The sampling time was a continuous seven-day period (24 h/day) for each sampler. Indoor samplers were placed approximately 2 m above the floor. Outdoor samplers were placed 2.5–3.5 m above the ground, under a well-ventilated plastic cover protecting them from rain and snowfall. The samplers were obtained from IVL Swedish Environmental Research Institute Ltd. (Gothenburg, Sweden). The samplers were analyzed by an accredited laboratory (IVL) specializing in analyzing such samplers, and were reported as average values across the 7-day measurement period. The concentration of indoor and outdoor PM10 was measured in parallel by direct DUST Track II Aerosol monitor (TSI Incorporated, St. Paul, MN, USA) during one day in each school. Temperature, relative humidity (RH), CO2 and PM10 were measured for two hours in each classroom, with a full class and during lectures. The outdoor levels were measured for one hour simultaneously the same day in each school.

Data from local monitoring stations

In order to compare our measurement data with the general air pollution in the city, and to study time trends in air pollution, air pollution data was collected from all nine local monitoring stations in Taiyuan. Annual mean values were available for SO2, NO2 and PM10 for 2010, 2011 and 2012. PM2.5 was not measured in Taiyuan until 2013. To get information on the ratio between PM2.5 and PM10 in the city, we collected annual means for PM2.5 and PM10 for 2013. In addition, we collected monitoring station data on SO2, NO2 and PM10 for the study period (two weeks in March 2010).

Data analysis

Questionnaire data was entered independently by two persons using Epidate 3.1 software. Differences in prevalence between 2010 and 2012 were tested by the McNemar test. For each student, the occurrence of any mucosal, skin, or general symptoms (weekly symptoms) was calculated in both the beginning and the end of the follow-up period. New onset (incidence) of any mucosal symptom was defined as the presence of at least one mucosal symptom at the end of the follow-up period but the absence of any mucosal symptom in the beginning. New onset of any skin or any general symptom was defined in a similar way. The reference group for calculating new onset was subjects not reporting the particular group of symptom neither in 2010 nor in 2012. Remission of a particular group of symptoms (mucosal, skin or general) was defined as presence of any symptom (e.g., mucosal) in the group in the beginning and absence of any mucosal symptom at the end of the follow-up. The reference group for calculating remission was subjects reporting the particular group of symptom in 2010 as well as in 2012. New onset and remission of SBS symptoms was defined in a similar way as in our previous study [26].

Multiple logistic regression was used to analyze associations between the dependent variables (SBS symptoms) and exposure (indoor exposure on classroom level or outdoor exposure on school level), controlling for age, sex, parental asthma or allergy, and keeping each exposure separate in the models. For all statistical analyses, a two-tailed tests and 5% significance level were applied. All statistical analyses were conducted using SPSS 20.0.

Results

In total, 2134 of 2335 pupils (91.4%) participated in the baseline questionnaire study in 10 schools (baseline). The mean age was 13.7 years (range 11–15 years). The follow-up study was restricted to those 1325 pupils (62.1%) who participated in both the initial study and the follow-up study and who stayed in the same classroom. We found no significant differences between participants (N = 1325) and non-participants (N = 809) with respect to asthma, atopy, smoking habits,parental asthma or allergy, or prevalence of any general symptom, any mucosal symptom, any skin symptom or any symptom improved when away from school (Table 1). The mean age was 13.4 years (SD = 0.70) among participants and 14.2 years (SD = 0.96) among non-participants (p = 0.69). However, the proportion of girls among the participants were higher (p = 0.02).

thumbnail
Table 1. Demographic data from baseline study (2010) comparing questionnaire data for participants (N = 1325) and non-participants (N = 809) in the two-year follow-up study.

https://doi.org/10.1371/journal.pone.0112933.t001

The cumulative incidence of asthma (ever had asthma) and tobacco smoking had increased during the follow-up period and there was a significant increase of any mucosal symptom, any general symptom, any dermal symptom and any symptom that improved when away from school (school-related symptoms). Among individual symptoms, most mucosal and general symptoms had increased (Table 2). Data on new onset (incidence) and remission of symptoms is given in Table 3. The incidence during the two-year period was highest for general symptom (33%) and lowest for skin symptoms (6%). The incidence of school-related general and mucosal symptoms was 11% and 15%, respectively while the incidence of school-related skin symptoms was low (3%). The remission of symptoms during the two-year period ranged from 21–38%, with the lowest remission for general symptoms and the high remission for skin symptoms.

thumbnail
Table 2. The prevalence of asthma, allergy, smoking and weekly symptoms in the last 3 months 2010 and 2012 among junior high school students in Taiyuan.

https://doi.org/10.1371/journal.pone.0112933.t002

thumbnail
Table 3. The number of cases and percentage of new onset and remission of SBS symptoms during the two-year follow-up (N = 1325).

https://doi.org/10.1371/journal.pone.0112933.t003

The buildings were constructed of concrete or bricks. No classroom had any mechanical ventilation or air-conditioning, opening windows was the only means of ventilation. The windows were mostly closed because of the cold climate. The classrooms had concrete floors without any paint. The floors were cleaned one to three times per day by means of wet mopping by the pupils. No visible sign of building dampness, water leakage, mould growth or water damage was observed in any of the selected classrooms, and very few classrooms had any indoor pot plants. The average indoor concentrations of SO2, NO2, O3 and PM10 were 68.0, 43.2, 8.6 and 129 µg/m3, respectively (Table 4). The average indoor/outdoor ratio was 37% for SO2, 91% for NO2, 48% for O3 and 77% for PM10. When comparing exposure data at baseline for schools participating (N = 8) and not participating (N = 2) in the longitudinal study, no major differences were observed (Table 4). As a next step, correlations between indoor environmental exposures were investigated. At higher indoor relative air humidity, levels of indoor NO2, PM10 and CO2 were higher. At higher indoor CO2, levels, indoor PM10 were higher. Room temperature was not significantly correlated with any exposure variable. There was a close correlation between indoor NO2 and SO2, but no significant correlations between other chemical air pollutants (Table 5).

thumbnail
Table 4. Average indoor and outdoor climate and concentration of air pollutants, measured at baseline (2010).

https://doi.org/10.1371/journal.pone.0112933.t004

thumbnail
Table 5. Correlation between indoor exposures (Pearson correlation) (N = 39).

https://doi.org/10.1371/journal.pone.0112933.t005

In Taiyuan there are nine monitoring stations for outdoor air pollution. Average data for SO2, NO2 and PM10 during the study period (2010–2012) was given in Table 6. There was a trend of decreased pollution levels for SO2 and PM10 and increased levels of NO2 during the follow-up period, but the differences were not large. Moreover, we compared mean air pollution values from the monitoring station for the two week study period in March 2010 with annual means for 2010. The monitoring data for SO2 during the two week study period was the same (100%) as the annual mean while the level of PM10 during the study period were 167% higher and the level of NO2 was 71% lower. In China, outdoor air pollution of fine particles (PM2.5) is currently a hot topic. In Taiyuan, PM2.5 was not measured until 2013. In 2013, the annual mean of PM2.5 was 77.7 µg/m3 at the monitoring stations measuring PM2.5 in Taiyuan, corresponding to 49.6% of the annual PM10 value for 2013 at the same stations.

thumbnail
Table 6. Annual means of outdoor exposures measured at monitoring stations.

https://doi.org/10.1371/journal.pone.0112933.t006

Associations between the prevalence of SBS symptoms and measured environment factors at baseline were studied by multiple logistic regression, adjusting for age, gender, parental asthma, and keeping each exposure factor separately in the models. Both indoor and outdoor SO2 were positively associated with any symptom improved when away from school (school-related symptoms). Indoor O3 was positively associated with any skin symptoms, and outdoor NO2 was negatively associated with any skin symptoms (Table 7).

thumbnail
Table 7. Associations between measured environmental factors and the prevalence of weekly symptoms at baseline in 2010 (N = 2134).

https://doi.org/10.1371/journal.pone.0112933.t007

As a next step, associations between new onset (incidence) of SBS symptoms and the exposures were analyzed by multiple logistic regression (Table 8). Indoor PM10 was positively associated with new onset of skin symptoms, mucosal symptoms, general symptoms and school-related mucosal and general symptoms. Classroom CO2 concentration was positively associated with new onset of mucosal symptoms, general symptoms and any symptom improved when away from school, including school-related mucosal and general symptoms. Classroom relative air humidity was positively associated with new onset of mucosal symptoms, general symptoms and any symptom improved when away from school, including school-related mucosal and general symptoms. Outdoor concentration of SO2 was positively associated with new onset of dermal symptoms, only. Outdoor NO2 was positively associated with new onset of dermal, general and mucosal symptoms. Outdoor PM10 levels were positively associated with new onset of dermal, general and mucosal symptoms as well as any symptom improved when away from school, including school-related mucosal and general symptoms (Table 8).

thumbnail
Table 8. Associations between measured environmental factors and onset (incidence) of weekly symptoms during the two-year follow-up from 2010 to 2012 (N = 1283).

https://doi.org/10.1371/journal.pone.0112933.t008

Remission of SBS symptoms in relation to air pollution levels were analyzed in the same way by multiple logistic regression (Table 9). Indoor PM10 level was negatively associated with remission of any mucosal symptoms and any symptom improved if away from school, including school-related mucosal and general symptoms. Classroom CO2 concentration and relative air humidity were negatively associated with remission of any symptom improved when away from school. Outdoor SO2 was negatively associated with remission of mucosal symptoms and outdoor NO2 and outdoor PM10 were negatively associated with remission of any symptom improved when away from school.

thumbnail
Table 9. Associations between measured environmental factors and remission of weekly symptoms during the two-year follow-up from 2010 to 2012 (N = 1283).

https://doi.org/10.1371/journal.pone.0112933.t009

Finally, associations between gender, parental allergy or asthma (heredity), pollen or pet allergen (atopy) and SBS symptoms were analysed, both at baseline and longitudinally (Table 10). In the cross-sectional analysis, girls reported less skin symptoms, less mucosal symptoms and less school-related mucosal symptoms. Parental asthma or allergy (heredity) was positively associated with all types of symptoms. In the longitudinal analysis, girls had a lower incidence of skin symptoms. Parental asthma or allergy (heredity) was associated with a higher incidence of mucosal symptoms, general symptoms and any symptom improved when away from school, including school-related mucosal and general symptoms. Pollen or pet allergy (atopy) at baseline was associated with a higher incidence of skin symptoms, only. No associations were found between personal risk factors and remission of symptoms.

thumbnail
Table 10. Associations between gender, pollen or pet allergy, parental allergy or asthma and weekly symptoms in cross-sectional and longitudinal analysis.

https://doi.org/10.1371/journal.pone.0112933.t010

Discussion

In our study among junior high school students in Taiyuan, a heavily polluted city, the prevalence of mucosal symptoms, general symptoms and school-related symptoms was relatively high at baseline and increased during the two-year follow-up. We found associations between indoor climate and ventilation and indoor and outdoor air pollution in the schools and different types of SBS symptoms. Higher concentrations of SO2, NO2, O3 and PM10 were positively associated with higher prevalence and higher incidence of SBS and negatively associated with remission of symptoms. Parental asthma or allergy (heredity), pollen or pet allergy (atopy) and male gender were important risk factors for prevalence and incidence of SBS. The study was performed in the same schools as our previous two-year longitudinal school study in Taiyuan performed in 2004–2006 [26]. Our current study could confirm findings from the previous study with respect to chemical air pollutants despite the environmental improvements that had taken place in the city. This suggests that the air pollution levels in Taiyuan in 2010–2012 were still high enough to cause impaired health. To our knowledge, our study is one of few longitudinal studies on SBS in relation to indoor and outdoor air pollution in schools in China.

Epidemiological studies can be affected by selection bias and information bias. The schools were randomly selected within Taiyuan city and first-year classes were randomly selected within the schools. The response rate in the initial study was 92%, 62% of which participated in the follow-up study. The participation rate in the follow-up was a bit low, but was mainly due to the lack of participation of two schools and the transfer of some pupils to other schools or other classrooms during follow-up. There was no indication of selection bias when comparing classes participating and not participating in the longitudinal study, except for a somewhat higher participation rate among girls. Concerning information bias, the same questionnaire was used in the current study as in the previous study from 2004–2006 [26]. The questionnaire data was collected one week before environment measurements, and exposure levels were unknown when the students answered the questionnaires, and there were no visible signs of microbial growth in any classroom. The study was done in the same month (March) both times, during normal lecturing activities. We measured chemical air pollutants using a badge type of diffusion sampler fully based on the theory for diffusion sampling [27]. With this sampler, the theoretical sampling rate can be used to calculate the pollutant concentrations [28], and movement of air inside the sampler resulting from wind induced turbulence [29] and other artifacts are minimized.

One limitation of our study is the short sampling time, 2 hours for temperature, relative air humidity, CO2 and PM10 and one week continuous air monitoring for chemical air pollutants (NO2, SO2, O3). Another limitation is that we only have exposure data measured at baseline. The advantage with having exposure data at baseline is that the exposure is measured before the change of symptoms. Data from local monitoring stations in the city suggests a reduction of SO2 and PM10 and an increase of NO2 levels during the study period but the changes were not large. Moreover, the level of SO2 during the two week measurement period (March 2010) was the same as the annual mean for that year but the levels of PM10 was higher and the levels of NO2 was lower when we did our measurements as compared to the annual mean. The absolute pollution levels measured during two weeks may not be representative for the long term mean exposure, but the relative ranking of the schools (rank order) can be assumed to be more stable and similar even if the absolute exposure levels vary over time. Another limitation of our study is that it focused on particular matter and chemical air pollutants, and did not measure allergens and microbial markers. In the previous study from 2004–2006, dust was collected by vacuum cleaning [8]. Some bacterial and fungal compounds were found to be protective while others were risk factors for SBS symptoms. However, since these microbial compounds are mainly from indoor sources, they should not be major confounders in our study measuring air pollutants mainly from outdoor sources. Another limitation is that we do not have data on the air pollution at home, where the children spend most of their time. However, at this age most children live near their school and it can be assumed that the general outdoor pollution levels are similar at home and at school, but ventilation habits may differ between the school and the home. Most of the limitations of our study would most likely lead to non-differential misclassification. In conclusion, we do not believe that the results and conclusions from our study were seriously biased by selection bias or information bias.

Shanxi province is a major coal mining area with one-third of China’s domestic coal production, and Taiyuan is a heavily industrialized area relying on coal combustion. The city is surrounded by mountains and has a heavy outdoor air pollution, especially during the heating season and especially for SO2 and particulate matter. Moreover, satellite monitoring has demonstrated that this area sometimes has one of the highest pollution levels of NO2 in the world [30]. In our previous school study from the same schools in 2004 [26], the weekly mean concentration of SO2 was 265 µg/m3 indoors and 713 µg/m3 outdoors. In our current study from 2010, the levels had decreased to 68.0 µg/m3 indoors and 183.5 µg/m3 outdoors. This is a about 4 times lower levels, suggesting a considerable environmental improvement with respect to SO2 levels in Taiyuan. In the previous study from 2004, the weekly mean concentration of NO2 was 39.4 µg/m3 indoors and 52.3 µg/m3 outdoors [26]. In our current study from 2010, levels were similar (43.2 µg/m3 indoors and 47.5 µg/m3 indoors). Finally, the weekly mean concentration of indoor O3 was 8.6 µg/m3 in our study, similar as in the previous study (10.1 µg/m3) in 2004. The weekly mean concentration of outdoor O3 was 18.1 µg/m3, in our study, around 1–1.5 times the outdoor levels of O3 (12.4 µg/m3) in the previous study. Our data were one week average, so they are not directly comparable with the WHO guidelines. The WHO air quality guideline for SO2 is 20 µg/m3 (24-hour mean) and 500 µg/m3 for a 10-min mean value. The WHO air quality guideline for NO2 is 40 µg/m3 (annual mean) and 200 µg/m3 for 1-hour mean. The WHO air quality guideline for O3 is 100 µg/m3 for a 8-h mean value [31]. The local government and environmental protection agency in Shanxi province have taken a series of measures to reduce level of SO2 and particulate matters recent years. Our pollutions measurements in the two school studies suggest that these measures have been effective. However, the levels of NO2, a pollutants mainly coming from vehicle exhaust, were still high and did not change over six years.

None of the schools had a mechanical ventilation system, and window opening was the only way to ventilate the classrooms. CO2 is an indication of ventilation flow in a room, and is related to the number of persons in the room as well as the air exchange rate. Typically, ventilation standards require that the CO2 level should be below 1000 ppm [32]. In the current study from 2010, the mean CO2 level was 1208 ppm but in the previous study from 2004 the mean level was much higher (2211 ppm) [26]. In the current study from 2010, both CO2 and RH were associated with an increased incidence of mucosal symptoms, general symptoms and symptoms improved if away from school, and decreased remission of symptoms improved if away from school. In the previous study from 2004–2006, we found negative association between indoor levels of CO2 and symptoms significant only found in the cross-sectional analysis [26]. One explanation of the different results from the two studies could be that when the levels of outdoor pollution has been reduced (2010 year study), air pollution from indoor sources becomes more important and then better ventilation in the classrooms, with lower values of CO2, leads to less SBS symptoms. Ventilation is an important factor in the indoor environment, especially in schools. A review of epidemiological studies on ventilation in buildings has concluded that higher ventilation rates in offices were associated with reduced prevalence of SBS symptoms [33]. One recent study has reported that at 1000 ppm CO2, compared to a CO2-level of 600 ppm, decision-making performance was reduced [34].

In our current study from March 2010, the mean temperature was 18.6 °C indoors and 2.8 °C outdoors. In the previous school study from December 2004 [26], the mean temperature was 14.7 °C indoors and −1.8 °C outdoors. In both surveys, the measurements were performed during heating season but not in the same month, so they were not directly comparable with each other. The higher classroom temperature in 2010 as compared to 2006 could partly be due to improved heating systems.

The indoor and outdoor PM10 levels were 129 µg/m3 and 168 µg/m3 respectively. These levels are higher than the WHO health based standard for PM10 of maximum 50 µg/m3 as a 24-h mean value [31]. In our study, we found that both indoor and outdoor PM10 was associated with increased incidence and decreased remission of most types of SBS symptoms. We found no previous school environment study on SBS symptoms in relation to indoor or outdoor PM10 levels, but one study reported an association between PM10 levels and reduced nasal patency [35]. Moreover, some studies have reported that ambient particulate matter can cause airway inflammation and oxidative stress [36], [37]. Our findings of both increased incidence and decreased remission of mucosal symptoms associated to PM10 are well in accordance with other data from schools [35][38]. Since we found health associations for PM10 only in the longitudinal analysis, our results indicates a need for more longitudinal school environment studies. Recently there has been a focus on fine particles (PM2.5) in ambient air in China. In Taiyuan, the first measurements of PM2.5 was performed one year after our study was finished (2013). Data from this year indicate that about 50% of the PM10 in outdoor air in Taiyuan consist of PM2.5. However, it is likely that the proportion of PM2.5 in indoor particles in classrooms in Taiyuan is somewhat lower, since indoor sources in schools mainly generate larger particles (PM10) to the classroom air [35], [39].

We found that both indoor and outdoor SO2 were positively associated with symptoms improved when away from school in the cross-sectional analysis. In the longitudinal analysis, outdoor SO2 was positively associated with new onset of dermal symptoms and negatively associated with remission of any mucosal symptoms. One study from Taiwan, China, found that the prevalence of allergic rhinitis was significantly associated with SO2 levels (OR = 1.43) [40]. A previous epidemiological study from four cities in China found that ambient levels of SO2 were positively associated with children’s respiratory symptoms [41]. In the previous school environment study from the same schools, we found a positive association between indoor levels of SO2 and prevalence of general, mucosal and skin symptoms [26]. In the current study we found a positive association between SO2 levels and incidence of skin symptoms. In contrast, in the previous school study from 2004 we found a negative association between SO2 levels and incidence of skin symptoms. We have no explanation to this discrepancy, which could be a chance finding.

In our study, we found that outdoor NO2 levels were associated with SBS. There were positive associations between NO2 concentration and increased incidence of skin, mucosal and general symptoms and a decreased remission of school-related symptoms. However, in the cross-sectional analysis we found a negative association between outdoor NO2 and prevalence of skin symptoms, which could be a chance finding. One previous study have demonstrated that an association between NO2 levels and prevalence of nasal catarrh, eye symptoms and eczema in 5–14 years old children [42]. In the previous Taiyuan school study from 2004, we found that NO2 levels in the classrooms were positively associated with prevalence of mucosal symptoms and symptoms improved if away from school [26].

It is well known that O3 can cause mucosal symptoms from the eyes, nose and lower respiratory tract. The associations between NO2 and O3 is complex, since NO from fresh traffic exhaust reacts with O3 to form NO2 but with an interaction of other pollutants such as volatile organic compounds (VOC) and particles. In the cross-sectional analysis in our study, indoor O3 concentration was positively associated with skin symptoms, only. Other school studies have reported associations between O3 and skin symptoms. In one Spanish study, exposure to O3 was associated with increased prevalence of skin rashes [43]. In another French study, a moderate increase in long-term exposure to background O3 was associated with an increase of atopic indicators in children [44].

In our current study, girls had less mucosal and skin symptoms and lower incidence of skin symptoms. Many previous studies have reported that women report more SBS than men [45], [46]. In the previous school study from the same school, we did not find any associations between gender and SBS. Further studies are needed on gender differences in SBS symptoms in Chinese school children.

In conclusion, SBS symptoms were common in school children in Taiyuan City, China, and symptoms increased during the two-year follow-up period from 2010 to 2012. Parental asthma and allergy (heredity) and pollen or pet allergy (atopy) can be risk factors for both prevalence and incidence of SBS symptoms which could indicate similar mechanisms behind SBS and development of asthma and allergy. Indoor and outdoor levels of air pollutants coming mainly from the outdoor environment, such as PM10, SO2 and NO2 were associated with prevalence, incidence and remission of SBS symptoms in school children. Moreover, we could demonstrate a beneficial effect of increased ventilation flow, measured as lower indoor CO2-levels on SBS. Despite the reduced levels of outdoor air pollution in Taiyuan in recent years, impaired health effects of the air pollution can still be detected. This indicates a need for further reduction of pollution levels in Shanxi province. Finally, our study suggests that longitudinal studies, including both incidence and remission data, are needed to evaluate health effects of indoor and outdoor air pollution in schools.

Acknowledgments

Thanks Institute of High School Student Health Care in Taiyuan. The authors would like to give many thanks to the participating pupils and teachers in the schools in Taiyuan City.

Author Contributions

Conceived and designed the experiments: XZ FL LZ ZZ DN. Performed the experiments: XZ ZZ DN. Analyzed the data: XZ ZZ. Contributed reagents/materials/analysis tools: XZ FL LZ ZZ DN. Contributed to the writing of the manuscript: XZ FL DN.

References

  1. 1. Redlich CA, Sparer J, Cullen MR (1997) Sick-building syndrome. Lancet 349: 1013–1016.
  2. 2. WHO (1983) Indoor air pollutants: exposure and health effects. WHO EURO Reports and studies World Health Organization, Denmark.
  3. 3. Skov P (1992) The sick building syndrome. Ann N Y Acad Sci 641: 17–20.
  4. 4. Saijo Y, Nakagi Y, Ito T, Sugioka Y, Endo H, et al. (2010) Dampness, food habits, and sick building syndrome symptoms in elementary school pupils. Environ Health Prev Med 15: 276–284.
  5. 5. Wang J, Li B, Yang Q, Yu W, Wang H, et al. (2013) Odors and sensations of humidity and dryness in relation to sick building syndrome and home environment in Chongqing, China. PLoS One 8: e72385.
  6. 6. Norback D, Edling C (1991) Environmental, occupational, and personal factors related to the prevalence of sick building syndrome in the general population. Br J Ind Med 48: 451–462.
  7. 7. Saijo Y, Nakagi Y, Ito T, Sugioka Y, Endo H, et al. (2009) Relation of dampness to sick building syndrome in Japanese public apartment houses. Environ Health Prev Med 14: 26–35.
  8. 8. Zhang X, Sahlberg B, Wieslander G, Janson C, Gislason T, et al. (2012) Dampness and moulds in workplace buildings: associations with incidence and remission of sick building syndrome (SBS) and biomarkers of inflammation in a 10 year follow-up study. Sci Total Environ 430: 75–81.
  9. 9. WHO (2009) Guidelines for indoor air quality, dampness and mould. World Health Organization, Denmark.
  10. 10. Norback D, Nordstrom K (2008) An experimental study on effects of increased ventilation flow on students’ perception of indoor environment in computer classrooms. Indoor air 18: 293–300.
  11. 11. Guo P, Yokoyama K, Piao F, Sakai K, Khalequzzaman M, et al. (2013) Sick building syndrome by indoor air pollution in Dalian, China. Int J Environ Res Public Health 10: 1489–1504.
  12. 12. Sahlberg B, Gunnbjornsdottir M, Soon A, Jogi R, Gislason T, et al. (2013) Airborne molds and bacteria, microbial volatile organic compounds (MVOC), plasticizers and formaldehyde in dwellings in three North European cities in relation to sick building syndrome (SBS). Sci Total Environ 444: 433–440.
  13. 13. Reinikainen LM, Jaakkola JJ (2001) Effects of temperature and humidification in the office environment. Arch Environ Health 56: 365–368.
  14. 14. Syazwan AI, Hafizan J, Baharudin MR, Azman AZ, Izwyn Z, et al. (2013) Gender, airborne chemical monitoring, and physical work environment are related to indoor air symptoms among nonindustrial workers in the Klang Valley, Malaysia. Ther Clin Risk Manag 9: 87–105.
  15. 15. Reinikainen LM, Jaakkola JJ (2003) Significance of humidity and temperature on skin and upper airway symptoms. Indoor air 13: 344–352.
  16. 16. Bjornsson E, Janson C, Norback D, Boman G (1998) Symptoms related to the sick building syndrome in a general population sample: associations with atopy, bronchial hyper-responsiveness and anxiety. Int J Tuberc Lung Dis 2: 1023–1028.
  17. 17. Apter A, Bracker A, Hodgson M, Sidman J, Leung WY (1994) Epidemiology of the sick building syndrome. J Allergy Clin Immunol 94: 277–288.
  18. 18. Norback D (2009) An update on sick building syndrome. Current opinion in allergy and clinical immunology 9: 55–59.
  19. 19. Ahman M, Lundin A, Musabasic V, Soderman E (2000) Improved health after intervention in a school with moisture problems. Indoor air 10: 57–62.
  20. 20. Salo PM, Sever ML, Zeldin DC (2009) Indoor allergens in school and day care environments. J Allergy Clin Immunol 124: 185–192, 192 e181–189; quiz 193–184.
  21. 21. Mendell MJ, Heath GA (2005) Do indoor pollutants and thermal conditions in schools influence student performance? A critical review of the literature. Indoor air 15: 27–52.
  22. 22. Daisey JM, Angell WJ, Apte MG (2003) Indoor air quality, ventilation and health symptoms in schools: an analysis of existing information. Indoor air 13: 53–64.
  23. 23. Lee SC, Chang M (2000) Indoor and outdoor air quality investigation at schools in Hong Kong. Chemosphere 41: 109–113.
  24. 24. Cai G-H, Hashim JH, Hashim Z, Ali F, Bloom E, et al. (2011) Fungal DNA, allergens, mycotoxins and associations with asthmatic symptoms among pupils in schools from Johor Bahru, Malaysia. Pediatric allergy and immunology: official publication of the European Society of Pediatric Allergy and Immunology 22: 290–297.
  25. 25. Meyer HW, Wurtz H, Suadicani P, Valbjorn O, Sigsgaard T, et al. (2004) Molds in floor dust and building-related symptoms in adolescent school children. Indoor air 14: 65–72.
  26. 26. Zhang X, Zhao Z, Nordquist T, Norback D (2011) The prevalence and incidence of sick building syndrome in Chinese pupils in relation to the school environment: a two-year follow-up study. Indoor air 21: 462–471.
  27. 27. Ferm M, Svanberg PA (1998) Cost-efficient techniques for urban and background measurements of SO2 and NO2. Atmos Environ 32: 1377–1381.
  28. 28. Mi YH, Norback D, Tao J, Mi YL, Ferm M (2006) Current asthma and respiratory symptoms among pupils in Shanghai, China: influence of building ventilation, nitrogen dioxide, ozone, and formaldehyde in classrooms. Indoor air 16: 454–464.
  29. 29. Campbell GW, Stedman JR, Stevenson K (1991) A survey of nitrogen dioxide concentrations in the United Kingdom using diffusion tubes. Atmos Environ 28: 477–486.
  30. 30. Richter A, Burrows JP, Nuss H, Granier C, Niemeier U (2005) Increase in tropospheric nitrogen dioxide over China observed from space. Nature 437: 129–132.
  31. 31. WHO (2005) WHO Air Quality Guidelines Global Update 2005. World Health Organization, Denmark.
  32. 32. ASHRAE (1989) Ventilation for Acceptable Indoor Air Quality. Atlanta, GA, Amercan Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc (Standard 62-1989).
  33. 33. Sundell J, Levin H, Nazaroff WW, Cain WS, Fisk WJ, et al. (2011) Ventilation rates and health: multidisciplinary review of the scientific literature. Indoor air 21: 191–204.
  34. 34. Satish U, Mendell MJ, Shekhar K, Hotchi T, Sullivan D, et al. (2012) Is CO2 an indoor pollutant? Direct effects of low-to-moderate CO2 concentrations on human decision-making performance. Environ Health Perspect 120: 1671–1677.
  35. 35. Simoni M, Annesi-Maesano I, Sigsgaard T, Norback D, Wieslander G, et al. (2010) School air quality related to dry cough, rhinitis and nasal patency in children. Eur Respir J 35: 742–749.
  36. 36. Oeder S, Dietrich S, Weichenmeier I, Schober W, Pusch G, et al. (2012) Toxicity and elemental composition of particulate matter from outdoor and indoor air of elementary schools in Munich, Germany. Indoor air 22: 148–158.
  37. 37. Oeder S, Jorres RA, Weichenmeier I, Pusch G, Schober W, et al. (2012) Airborne indoor particles from schools are more toxic than outdoor particles. Am J Respir Cell Mol Biol 47: 575–582.
  38. 38. Norback D, Torgen M, Edling C (1990) Volatile organic compounds, respirable dust, and personal factors related to prevalence and incidence of sick building syndrome in primary schools. Br J Ind Med 47: 733–741.
  39. 39. Fox A, Harley W, Feigley C, Salzberg D, Toole C, et al. (2005) Large particles are responsible for elevated bacterial marker levels in school air upon occupation. J Environ Monit 7: 450–456.
  40. 40. Hwang BF, Jaakkola JJ, Lee YL, Lin YC, Guo YL (2006) Relation between air pollution and allergic rhinitis in Taiwanese schoolchildren. Respir Res 7: 23.
  41. 41. Zhang JJ, Hu W, Wei F, Wu G, Korn LR, et al. (2002) Children’s respiratory morbidity prevalence in relation to air pollution in four Chinese cities. Environ Health Perspect 110: 961–967.
  42. 42. Mengersen K, Morawska L, Wang H, Murphy N, Tayphasavanh F, et al. (2011) Association between indoor air pollution measurements and respiratory health in women and children in Lao PDR. Indoor air 21: 25–35.
  43. 43. Suarez-Varela MM, Gallardo-Juan A, Garcia-Marcos L, Gimeno-Clemente N, Silvarrey-Varela AL, et al. (2013) The impact of atmospheric pollutants on the prevalence of atopic eczema in 6–7-year-old schoolchildren in Spain; ISAAC Phase III. Iran J Allergy Asthma Immunol 12: 220–227.
  44. 44. Penard-Morand C, Charpin D, Raherison C, Kopferschmitt C, Caillaud D, et al. (2005) Long-term exposure to background air pollution related to respiratory and allergic health in schoolchildren. Clin Exp Allergy 35: 1279–1287.
  45. 45. Soine L (1995) Sick building syndrome and gender bias: imperiling women’s health. Soc Work Health Care 20: 51–65.
  46. 46. Sun YX, Zhang YF, Bao LJ, Fan ZG, Wang DS, et al. (2013) Effects of gender and dormitory environment on sick building syndrome symptoms among college students in Tianjin, China. Build Environ 68: 134–139.