A Quantitative MRI Method for Imaging Blood-Brain Barrier Leakage in Experimental Traumatic Brain Injury

  • Wei Li ,

    Contributed equally to this work with: Wei Li, Justin Alexander Long

    liw5@uthscsa.edu (WL); duongt@uthscsa.edu (TQD)

    Affiliations Research Imaging Institute, University of Texas Health Science Center at San Antonio, San Antonio, Texas, United States of America, Department of Ophthalmology, University of Texas Health Science Center at San Antonio, San Antonio, Texas, United States of America

  • Justin Alexander Long ,

    Contributed equally to this work with: Wei Li, Justin Alexander Long

    Affiliation Research Imaging Institute, University of Texas Health Science Center at San Antonio, San Antonio, Texas, United States of America

  • Lora Talley Watts,

    Affiliations Research Imaging Institute, University of Texas Health Science Center at San Antonio, San Antonio, Texas, United States of America, Department of Cellular and Structure Biology, University of Texas Health Science Center at San Antonio, San Antonio, Texas, United States of America, Department of Neurology, University of Texas Health Science Center at San Antonio, San Antonio, Texas, United States of America

  • Zhao Jiang,

    Affiliation Research Imaging Institute, University of Texas Health Science Center at San Antonio, San Antonio, Texas, United States of America

  • Qiang Shen,

    Affiliation Research Imaging Institute, University of Texas Health Science Center at San Antonio, San Antonio, Texas, United States of America

  • Yunxia Li,

    Affiliation Research Imaging Institute, University of Texas Health Science Center at San Antonio, San Antonio, Texas, United States of America

  • Timothy Q. Duong

    liw5@uthscsa.edu (WL); duongt@uthscsa.edu (TQD)

    Affiliations Research Imaging Institute, University of Texas Health Science Center at San Antonio, San Antonio, Texas, United States of America, Department of Ophthalmology, University of Texas Health Science Center at San Antonio, San Antonio, Texas, United States of America, Department of Neurology, University of Texas Health Science Center at San Antonio, San Antonio, Texas, United States of America, South Texas Veterans Health Care System, Department of Veterans Affairs, San Antonio, Texas, United States of America

Abstract

Blood-brain barrier (BBB) disruption is common following traumatic brain injury (TBI). Dynamic contrast enhanced (DCE) MRI can longitudinally measure the transport coefficient Ktrans which reflects BBB permeability. Ktrans measurements however are not widely used in TBI research because it is generally considered to be noisy and possesses low spatial resolution. We improved spatiotemporal resolution and signal sensitivity of Ktrans MRI in rats by using a high-sensitivity surface transceiver coil. To overcome the signal drop off profile of the surface coil, a pre-scan module was used to map the flip angle (B1 field) and magnetization (M0) distributions. A series of T1-weighted gradient echo images were acquired and fitted to the extended Kety model with reversible or irreversible leakage, and the best model was selected using F-statistics. We applied this method to study the rat brain one hour following controlled cortical impact (mild to moderate TBI), and observed clear depiction of the BBB damage around the impact regions, which matched that outlined by Evans Blue extravasation. Unlike the relatively uniform T2 contrast showing cerebral edema, Ktrans shows a pronounced heterogeneous spatial profile in and around the impact regions, displaying a nonlinear relationship with T2. This improved Ktrans MRI method is also compatible with the use of high-sensitivity surface coil and the high-contrast two-coil arterial spin-labeling method for cerebral blood flow measurement, enabling more comprehensive investigation of the pathophysiology in TBI.

Introduction

The blood-brain barrier (BBB) plays a vital role in regulating the entry of blood-borne factors and circulating immune cells into the brain, hereby providing a highly stable biochemical environment for the normal functioning of neuronal cells. The integrity of the BBB can be disrupted by the translational and rotational forces in traumatic brain injury (TBI). The resulting BBB damage can evolve dynamically in both time and space with studies showing multi-phasic characteristics [1]. BBB leakage can lead to an imbalance of electrolytes, edema formation, inflammation, etc., and ultimately delayed neuronal dysfunction and degeneration [2]. There is a growing consensus that post-traumatic BBB disruption is one of the major factors that contribute to increased severity of TBI [3]. BBB has also been suggested as a target for therapeutic invention, as a normally functioning BBB is important for restoring brain hemostasis, and provides an optimal environment for neuronal repair [2], [4].

Quantitative assessment of BBB permeability is of particular importance for studying the disease pathophysiology and for optimizing therapeutic interventions in TBI. Traditional histological Evans Blue extravasation has been widely used to measure BBB leakage following TBI [1], [5], [6]. However, this method requires the sacrifice of the animals and does not permit for longitudinal assessments. Dynamic contrast enhanced (DCE)-MRI provides a promising alternative for noninvasive longitudinal assessment of the opening of BBB [7]. Unlike conventional T1-weighted images or T1 maps that are influenced by multiple non-physiological factors, e.g. timing, image acquisition, etc., DCE-MRI provides quantitative assessment of the diffusive transport of T1-enhancing agents, e.g. gadolinium-diethylenetriamine pentaacetic acid (Gd-DTPA), across the BBB. By fitting the mechanistic tracer kinetic models, DCE-MRI yields the volume transfer coefficient Ktrans, the extracellular extravascular space ve, etc. Currently, there is a consensus that Ktrans best reflects tissue permeability alterations and should be the primary end point of data fitting of DCE-MRI [7], [8].

Ktrans-MRI has been widely used to study stroke [9], [10], [11] and, to a much lesser extent, TBI. A recent study reported that Ktrans correlated with T2 lesion volume and the extent of injury in a rabbit weight-drop model of TBI [12]. A subsequent longitudinal study revealed different trajectories of BBB evolutions in focal and perifocal lesion areas using the same TBI model [13]. The focal lesion area showed increased Ktrans 3 h post-TBI, that peaked at 3 days, and remained higher than sham-operated animals at 7 and 30 days, while the perifocal lesion area showed increased Ktrans at 1, 3 and 7 days, and normalized Ktrans at 30 days [13]. Although there is a need for systematic investigation of post-traumatic BBB evolution under various conditions, Ktrans MRI is still not widely used in experimental or clinical TBI, because it is generally noisy and has low spatial and temporal resolution.

In this study, we improved the Ktrans MRI method by improving signal-to-noise ratio (SNR) and spatiotemporal resolution for longitudinal evaluation of BBB alterations in experimental TBI. To achieve the desired SNR, we used a high-sensitivity surface transceiver coil and a high field Bruker 7T scanner. To overcome the signal drop off profile associated with the use of a surface coil, the flip angle and the M0 distributions were measured using an optimized pre-scan module. The dynamic data were acquired using a fast gradient echo sequence. The arterial input function (AIF) was determined using the data and the scaling approach described in [14], [15]. The Ktrans map was derived by fitting the data to the extended Kety model with irreversible or reversible leakage, followed by model selection using F-statistics. We applied this method to an established controlled cortical impact model of TBI, and compared spatial profiles of BBB permeability changes against Evans Blue extravasation and cerebral edema indicated by T2 abnormality.

Materials and Methods

Animal Models

All animal procedures were approved by the Institutional Animal Care and Use Committee of University of Texas Health Science Center at San Antonio. TBI was performed using a controlled cortical impact (CCI) model as described previously [16], [17]. Briefly, male Sprague Dawley rats (250–350 g, n = 3) were anesthetized initially with 5% isoflurane mixed with room air and maintained at 1.5% isoflurane throughout all surgical procedures. A Ø5 mm craniotomy was produced over the left forelimb somatosensory cortex (S1: 0.25 mm anterior and 3.5 mm lateral to bregma), revealing the dura mater. The intact dura mater was impacted (Precision Systems and Instrumentation, LLC, Fairfax Station, Virginia) with a Ø3 mm tip (5.0 m/s, 250 µs dwell time, 1 mm depth) to emulate a mild focal TBI. The cranial opening was sealed with bone wax following the impact.

MRI

MRI was performed on a high field Bruker 7 Tesla BioSpec MRI scanner with a custom-made surface coil for brain imaging. The animal was secured in a custom built, MRI compatible, rat head stereotaxic holder with ear and tooth bars, and was scanned under 1.2% isoflurane. End-tidal CO2 was monitored via a SurgiVet capnometer (Smith Medical, Waukesha, WI, USA). Noninvasive end-tidal CO2 values have been calibrated previously against invasive blood gas samplings under identical settings. The heart rate and blood-oxygen saturation level were also monitored using a MouseOx system (STARR Life Science, Oakmont, PA, USA).

Ktrans-MRI (19.4 mins).

All Ktrans MRI data were acquired using a 2D multi-slice FLASH sequence. A pre-scan module was used to determine the flip angle and M0 distribution, which includes 3 FLASH scans with different TRs: 64 ms (scan 1), 200 ms (scan 2) and 3000 ms (scan 3). The rest of imaging parameters are: five 1.0-mm coronal slices, TE = 2 ms, FOV = 2.2×2.2 cm2, 128×128 data matrix and 30o nominal flip angle. The pre-scan takes 7.4 min. Dynamic scans use a TR of 64 ms, and otherwise identical sequence parameters. After baseline data were acquired for 2 min, a bolus (0.2 ml/kg) of gadodiamide (GE Healthcare, USA) was injected intravenously through the tail vein, during which the dynamic scan was continued. A total of 90 dynamic images were acquired with a temporal resolution of 8 s, lasting 12 min total.

T2 map (9.5 mins).

T2-weighted images were acquired using fast spin-echo (FSE) sequence with TR = 3 s (90o flip angle), effective TE = 18, 54, 90 and 126 ms, 4 echo train length. The other parameters were: seven 1.0-mm coronal images, FOV = 2.56×2.56 cm2, matrix 96×96 and reconstructed to 128×128, and 8 transients for signal averaging.

Ktrans Mapping

The steady-state spoiled gradient echo (GRE, acquired using the 2D FLASH sequence) signal amplitude for a given TR (MTR) can be related to M0, R1 and α as follows:(1)where is a function of both spatial location r and coil sensitivity . To minimize the R2* signal decay, a single-echo GRE scan was used with minimum TE and a low dose of gadolinium. As an approximation, was used in the subsequent calculation. A pre-scan module composed of three GRE scans was used to determine flip angle (α) and tissue magnetization (M0).

For flip angle mapping, simulations using Eq. 1 show that the ratio of GRE magnitudes at TRs of 200 ms and 64 ms depends strongly on α, but very weakly on T1 (Fig. 1C). Given the narrow T1 distribution of brain tissue, a raw α (or B1+) map can be obtained from the ratio map with a fixed T1 value. Assuming α is a smooth function of location, the final α map can be obtained after smoothing.

thumbnail
Figure 1. Determination of flip angle distribution.

(A) T1 map of a healthy rat brain acquired using an inversion recovery sequence. (B). Histogram of T1 distribution in the brain, showing the majority of T1 was within the range of 1.5 to 2.1 s. (C) The relationship between the ratio of M200 ms/M64 ms, T1 and flip angle. This simulation showed that the ratio depends weakly on T1 by mainly on the flip angle distribution. (D) and (E) were the magnitude of GRE signal at TR of 200 and 64 ms. (F) The raw flip angle map determined from the ratio of M200 ms/M64 ms. (G) The final flip angle map after a smooth fitting.

https://doi.org/10.1371/journal.pone.0114173.g001

For M0 determination, according to Eq. 1, the GRE signal becomes less dependent on T1 with increasing TR. With a long TR of 3000 ms, GRE magnitude depends primarily on sin(α) for small to medium flip angles (α<45°), but very weakly on T1. Given the normal flip angle of 30°, the actual flip angle of the brain tissue is within the range of 15 to 45°; therefore, M0 can be determined from the long TR scan and the flip angle distribution as follows: (2)

Given the smooth α distribution, high-SNR M0 map, and dynamic scans using sensitive surface coil at high field, dynamic R1 map was obtained using Eq. [1] with sufficient SNR.

The AIF was determined using the data and the scaling approach by Ewing and colleagues [14], [15]. Briefly, the mean AIF (AIFmean) was measured in a group of male rats (approximately 300 g) using the custom-synthesized radiolabeled Gd-DTPA [14]. Assuming the plasma volume was 1% and there was no BBB leakage in the contralesional side of caudate-putamen (CPU), the AIF was determined using the following scaling: (3)

The R1 and the AIF were then used to fit the extended Kety model: (4)where and are tissue and plasma gadolinium concentrations, and is the reversible mass transfer coefficient. In this study, the R1 and scaled AIF values were directly used for data fitting without further conversion to concentrations using the relativity of contrast agent. Since it is difficult to obtain acceptable Ktrans maps by simultaneously fitting all three parameters, we used the model selection approach by Ewing and colleagues [15] to select a simpler model that could sufficiently describe the dynamic contrast change. Data was fit to the extended Kety model with the two following assumptions as described by Ewing and colleagues [15]: (5)

For model selection, the irreversible model is selected, unless the reversible model yields a statistically significant better fit. The cut-off criteria use the F-statistic, which can be calculated using the summed squared residues (SSE) and the number of samples (N) is as follows:(6)where the subscript represents the corresponding model. The final selection mask is determined as:(7)

The threshold for F-statistic (F0) was set as 10 (P<0.05). The final Ktrans map was then determined as: (8)

All the calculations were performed using Matlab R2011b (Mathworks, Natick, MA).

Histology

BBB permeability was evaluated using Evans Blue (EB) extravasation as described previously [18], [19]. Briefly, 1 mL of 4% EB (Sigma-Aldrich, USA) solution was injected into the tail vein immediately after the dynamic scan and allowed to circulate for 1 hour. The rats were then transcardially perfused with heparinized saline solution followed by 4% paraformaldehyde. Brains were removed and cut into 1 mm slices to match the slice orientation and position of the MRI scans. The brain sections were imaged using an optical scanner. The brain regions stained with blue color indicate the leakage of EB bound to plasma albumin that moved across the impaired BBB.

Statistics

Data was presented as the mean ± standard error of the mean. Unpaired Student t-tests were used for comparisons between Ktrans values determined by different methods. Bonferroni correction was used to correct P-values for multiple comparisons. To evaluate the nonlinearity of Ktrans-T2 relationship, the data was fit to a quadratic function, using the Matlab statistics toolbox, which gives both the coefficient and the corresponding P-value. Statistical significance was set at P<0.05.

Results

Flip angle and M0 determination

Fig. 1A shows a T1 map of a rat brain obtained using an inversion recovery method. The T1 values were in the range of 1.5 to 2.1 s (using a threshold of 0.3% according to the histogram shown in Fig. 1B), with a mean of 1.8 s. Given this narrow range of T1 variation, the ratio of M200 ms/M64 ms was dominated by the flip angle variation and was not significantly affected by the T1 distribution (Fig. 1C). Assuming a fixed T1 value of 1.8 s, a raw flip angle map (Fig. 1F) was determined from the ratio of M200 ms (Fig 1D) and M64 ms (Fig. 1E). The final flip angle distribution was then obtained after a smooth fitting (Fig. 1G).

As shown in Fig. 2A, at a long TR of 3000 ms, the M3000 ms was primarily determined by the flip angle, but was not on significantly affected by the T1 distribution. Therefore, the M0 distribution (Fig. 2C) was determined by dividing the M3000 ms (Fig. 2B) by the sine of the flip angle (Fig. 1G).

thumbnail
Figure 2. Quantification of M0.

(A) Simulation showed that at long TR of 3000 ms, the GRE signal was primarily dependent on flip angle for small to medium flip angles (<45o), but with negligible dependence on the T1. (B) Magnitude of GRE signal at TR of 3000 ms. (C) M0 map derived by dividing M3000 ms by sin(α).

https://doi.org/10.1371/journal.pone.0114173.g002

Dynamic R1 mapping

Fig. 3A simulated the changes of GRE signal with the flip angle and R1 values using Eq. 1. The GRE signal showed good sensitivity to R1 changes for flip angles larger than 15o, which can be satisfied by the majority of brain tissue as shown in Fig. 1G. Given flip angle and M0 distribution, the R1 values (Fig. 3C) can be determined using Eq. 1 from the fast dynamic scan (Fig. 3B) at a high spatial resolution. The baseline R1 was subtracted from the time series to calculate the ΔR1 maps, which are linearly related to the changes of contrast agent concentration.

thumbnail
Figure 3. R1 mapping.

(A) Dependence of GRE signals on R1 and flip angles. (B) T1-weighted image. (C) R1 map.

https://doi.org/10.1371/journal.pone.0114173.g003

AIF determination

From the ΔR1 maps, a region of interest was manually selected in the region of contralesional caudate putamen (Fig. 4A). The signals were averaged to derive the curve shown in Fig. 4B. Using the signal from 3 to 9 min post contrast agent infusion, the group AIF data were scaled assuming a 1% plasma volume in the caudate putamen and that the caudate putamen had no BBB leakage (Fig. 4D, blue solid line). From the raw image, we selected the voxel in the center of superior sagittal sinus to minimize potential partial volume effects (Fig. 4C), which gave a signal profile (Fig. 4D, dotted red line) similar to the scaled group AIF data. This agreement supported the validity of the scaling approach.

thumbnail
Figure 4. Estimation of AIF.

(A) The area selected in contralesional CPU for scaling the group-averaged AIF data. (B) The averaged signal intensity change in CPU from the area determined in (A). (C) The voxel selected to generate the venous input function as shown as the red dotted line in (D). The agreement of the scaled AIF with the determined VIF indicated the validity of the scaling method.

https://doi.org/10.1371/journal.pone.0114173.g004

Fitting data to tracer kinetic models

Using Model 2, the fitted Ktrans showed good image quality (Fig. 5A). In comparison, the fitted Ktrans map using Model 3 was significantly noisier (Fig. 5B). Using F-statistics, the majority of voxels could be sufficiently described by Model 2, while much fewer voxels, especially in the injured tissue near the brain boundary, should be fitted by Model 3 (Fig. 5C). The final Ktrans map (Fig. 5D) was determined by combining the Ktrans maps obtained using the two models according to Eq. [8]. Using model selection, the final Ktrans map showed good image quality. The Dice's coefficient between the final Ktrans and Model 2 is 0.87±0.01, and is 0.13±0.01 between the final Ktrans and Model 3 (n = 3).

thumbnail
Figure 5. The fitting to different models and model selection.

(A) Ktrans fitted using model 2, the irreversible leakage model. (B) Ktrans fitted using model 3, the reversible leakage model. (C) Mask for model selection. (D) Final Ktrans by combining (A) and (B) using the mask as shown in (C) according to Eq. 8.

https://doi.org/10.1371/journal.pone.0114173.g005

Fig. 6 illustrated the impact of model selection on the Ktrans determination in this TBI brain. Along the red dotted line (Fig. 6A), Model 3 was selected more in the impact region, and was selected less in the remote region (Fig. 6B), when compared to Model 2. For further comparison, three different ROIs were drawn in the focal lesion, perifocal, and remote regions. The focal lesion region (Fig. 6C, ROI #1) showed the strongest BBB leakage, in which 100% of the voxels were better fit by Model 3 with reversible leakage. If reversible flux was neglected, the Ktrans value was significantly underestimated (P<0.01, Fig. 6D). In the perifocal region (Fig. 6C, ROI #2), 19% voxels were better fit by Model 3. Ktrans values determined by Model 2 and Model 3 were similar (P = 0.5). In the healthy region remote from the impact site (Fig. 6C, ROI #3), only 6% of voxels were better fit by Model 3. If reversible leakage was applied to all voxels (Model 3), the Ktrans was much nosier and significantly overestimated (P<0.01).

thumbnail
Figure 6. Ktrans values using different models in a representative TBI brain.

A: The location for the selected voxels for the voxel-wise intensity comparison in panel B. C: Label of ROIs. D: The Ktrans values in these ROIs using different approaches. Data were presented as mean ± standard error of each ROI.

https://doi.org/10.1371/journal.pone.0114173.g006

Ktrans vs. EB extravasation and T2

Fig. 7A shows the whole brain with EB staining. Extensive tissue damage can be easily identified as indicated by the white arrow. The T1-weighted contrast enhancement (ΔT1W, Fig. 7B), Ktrans map (Fig. 7C) and T2 map (Fig. 7D) of the same TBI brain were compared with the corresponding tissue slice with EB extravasation (Fig. 7E). Compared to the qualitative ΔT1W with higher SNR, Ktrans provided slightly lower but reasonably good image quality with the ability to make quantitative measures of BBB permeability. Both Ktrans and EB staining provided good delineation of BBB leakage in the region of focal lesion (green arrow). Compare to blurred boundaries in EB staining, Ktrans gave sharper boundaries of BBB leakage. The Ktrans heterogeneity showed similar features as the T2 map. There was a difference in the Ktrans maps and the EB staining. The Ktrans maps also showed hyper-intensities at the brain boundaries, whereas no EB staining did not (red arrow).

thumbnail
Figure 7. Comparison of EB staining, T1-weighted contrast enhancement, T2, and Ktrans map.

A: Whole brain images of EB staining. B: T1-weighted (T1W) signal enhancement. C: Ktrans map. D: T2 map. E: the corresponding axial slice of EB staining. The green arrow pointed to the focal lesion regions showing BBB leakage by both Ktrans MRI and EB staining. The red arrow shows significant increased intensity in Ktrans map but no leakage by EB extravasation.

https://doi.org/10.1371/journal.pone.0114173.g007

Fig. 8 compares a Ktrans map (Fig. 8A) with a T2 map (Fig. 8B). Both increased BBB permeability and increased T2 were located underneath the impact site. However, the degrees of increase between the two were not the same. A series of ROIs of the impact, the perifocal and the remote regions were drawn in the Ktrans and T2 maps (Fig. 8C). Care was taken to exclude voxels at the edges of the brain (at least 1 voxel) to minimize the effect of hyper-intensity along the boundary of the brain. A nonlinear relationship was observed between the increased T2 and the increased BBB leakage (Fig. 8D). The data was fit to a quadratic function (black line). The resulting coefficient for the quadratic term is 3.0×10−5, which is statistically significant (P<0.0001).

thumbnail
Figure 8. Comparing Ktrans map with T2.

A: Ktrans, B: T2, C: ROI labels. D: Ktrans and T2 values for the same ROIs as shown in C. The solid black line represented the quadratic function (y = 0.1037−0.0035x+2.98×10−5x2) obtained by the fitting.

https://doi.org/10.1371/journal.pone.0114173.g008

Discussion

In this study, we developed a Ktrans MRI method to quantify BBB leakage with high spatiotemporal resolution for a dynamic scan and sufficient image quality for application in TBI. This method utilized a high field 7 Tesla Bruker BioSpec MRI scanner and a sensitive surface coil. To overcome the signal drop off profile of the surface coil, a 3-scan module was used to determine the flip angle and M0 prior to the dynamic scan. The R1 maps were then determined using the GRE signal equation with known flip angle and M0, and the AIF was determined using scaled group-average AIF data. The obtained Ktrans map provided a quantitative map of the BBB leakage around the impact region that matches what was outlined by the Evans Blue extravasation. A nonlinear relationship between Ktrans and T2 was observed in the impact site and surrounding regions. This Ktrans MRI method provided a useful tool for longitudinal monitoring of BBB opening and for investigating the pathophysiology in experimental TBI.

Impact of surface transceiver coil on R1 mapping

Surface coils generally provide better signal sensitivity for preclinical scans than conventional volume coils. However, the use of surface coils for RF transmission leads to significant flip angle variation across the brain. In this study, we used dual-TR FLASH scans to measure the flip angle distribution. Since the T1 of the majority of the brain tissue is in the range of 1.4 to 2.1 s, the influence of T1 on the flip angle calculation was small (Fig. 1C). As such, a mean value of 1.8 s was used for deriving the raw flip angle map (Fig. 1F). A spatial smoothing was performed since T1 variation (in white matter, blood and the CSF) was generally distributed throughout the brain, and the flip angle should not have large local variations. In addition, this flip angle mapping method used the same sequence as the subsequent dynamic scans, thereby avoiding different distortions associated with different sequences.

Another issue with the surface receiver coil was the signal drop off, which was apparent in the long TR scan for M0 mapping (Fig. 2). Fortunately, the SNR of this scan is generally high owing to the long scan time. For scans with shorter TRs (for both flip angle mapping and dynamic scans), the signal intensity was much more homogenous (Fig. 1 and Fig. 3), due to the signal increase with smaller flip angles (according to Eq. 1). As a result, the R1 values of the deeper structures can be detected without significantly compromising SNR. From Fig. 3A, the sensitivity T1-weighted signal to gadolinium concentration was also related to the flip angle (Fig. 3A). With the nominal flip angle of 30o, the real flip angle gradually decreases from approximately 45o at the top of the brain to approximately 15o at the bottom of the brain. The T1-weighted signal has sufficient sensitivity for this entire range of flip angle distribution.

Determination of arterial input function

Accurate determination of AIF for preclinical MRI is non-trivial, given the fast arterial blood flow and the small dimensions of rodent brains. As such, different strategies have been proposed to mitigate this difficulty. For example, AIF determined from other imaging modalities has been used for fitting Ktrans [10], alternative reference region approaches have been developed to eliminate the use of AIF [20], and venous blood signals have also been employed to determine the vascular input function (VIF) instead of AIF [21]. In this study, we adopted the established approach by Ewing and colleagues [14], [15], and used a scaled group average AIF determined previously from radio-labeled Gd-DTPA. Although we could obtain similar VIF profiles from the veins to cross-validate the scaling approach, it should be noted that the accuracy of the VIF is poor due to the wash-in effects and its reproducibility cannot be guaranteed, so we chose to utilize the scaled group AIF data in the model fitting.

Fitting to tracer kinetic models and model selection

To achieve the desirable image quality for Ktrans, we used model selection as described by Ewing and colleagues [15]. For TBI, the reversible leakage model was necessary for the focal lesion, as shown by (Fig. 6B). Significant underestimation was observed if the reversible leakage was neglected (Fig. 6D). This result indicated that the Ktrans was sufficiently large, so that the contrast agent can accumulate to a significant amount in the extracellular extravascular space to allow a significant reversible flux of contrast agent back to the plasma. In other region, the irreversible leakage model was sufficient, which is consistent with the existing knowledge that intact brain tissue has negligible contrast agent leakage. Overall, the model selection approach was necessary to ensure that Ktrans was not underestimated in regions with significant reversible leakage and provided sufficient SNR for the whole brain.

Spatiotemporal resolution

Look-Locker type of sequences have also been previously used in DCE-MRI studies [22]. While such methods allow independent R1 mapping at each time point, it has much lower temporal resolution and lower SNR compared with the gradient-echo methods used in this and other studies [23], [24]. While some recent studies achieved higher temporal resolution (4 to 6 s per image), the 8-s temporal resolution for the dynamic scan in this study was sufficient for TBI studies, since the BBB leakage is generally much lower than in tumors [23], [24]. The slightly lower temporal resolution allows higher spatial resolution and more spatial coverage, which is desirable for TBI studies.

Ktrans MRI vs. Evans Blue extravasation

Histological validation of MRI methods is challenging because MRI and histology do not measure exactly the same physiological parameters. Ktrans MRI indirectly measures the water signals due to the leakage of small-molecular-weight gadodiamide (592Da), whereas the EB method directly measures the leakage of EB bound to serum proteins (65 kDa). The timings for contrast leakage over which the two methods sampled also differ. Ktrans MRI measures leakage via a single bolus of contrast dynamically, whereas EB measures leakage of accumulated EB over an hour at a steady state. Nevertheless, Fig. 7 shows that the leakage determined using Ktrans generally matched Evans blue extravasation in the focal lesion region. However, it appeared that EB did penetrate deeper into the surrounding tissue than the gadodiamide contrast agent measured by MRI. Some possible reasons are the differences in molecular weights, timing, interactions with vessel walls and the surrounding cellular components between EB and gadodiamide molecules. Another reason could be further diffusion of EB during the transcardial perfusion with heparinized saline solution. In addition, Ktrans MRI also showed higher intensities at the brain boundaries. Based on the dynamic signal changes, the increased Ktrans at the brain boundaries was not from parenchymal tissues or fat from the skull and was not due to partial volume effects. They were likely due to contrast agent leakage from vasculatures outside the brain, or from damaged tissue at the impact site. Therefore, care should be taken when analyzing voxels close to the brain boundary, as the increased Ktrans value may not represent true BBB leakage. Nevertheless, Ktrans provides a quantitative measure of BBB leakage non-invasively, allowing the longitudinal measure of BBB changes, something that is not possible using the EB approach. Since EB interferes with lesion staining, additional histological staining was not performed. Previously, a detailed comparison between T2 and Nissl staining has been performed [17]. Overall, our results suggest that the Ktrans heterogeneity follows the lesion variation shown in T2 better than EB staining.

Compatibility with other methods for multi-modal MRI

Our motivation to further develop the Ktrans MRI method using a surface coil to quantify BBB permeability was to obtain a method that would also be compatible with arterial spin labeling measurements. Arterial spin labeling uses a separate neck coil to measure cerebral blood flow [25], [26], [27]. There is substantial evidence that blood flow is markedly perturbed following TBI but CBF is seldom measured in TBI. Acute and chronic perfusion abnormality could have a negative impact on tissue viability following TBI. Future studies will correlate Ktrans MRI data with blood flow, diffusion, and T2 data longitudinally in the same animal to better understand the pathophysiology of TBI and to better evaluate potential therapies.

Conclusions

We developed a Ktrans MRI method for measuring BBB permeability using a surface coil and a gradient-echo based pulse sequence. The obtained Ktrans map provided excellent SNR, high spatial resolution and spatial coverage. The BBB leakage determined using Ktrans agrees well with Evans Blue extravasation, and displayed a nonlinear relationship with T2. Future studies will use this method to systematically evaluate the longitudinal progression of BBB leakage following TBI. This approach can also be used to investigate other neurological disorders.

Acknowledgments

The authors were grateful for the group AIF data and the discussions with Dr. James R. Ewing from the Henry Ford Hospital.

Author Contributions

Conceived and designed the experiments: WL JAL TQD. Performed the experiments: WL JAL LTW ZJ QS YL. Analyzed the data: WL. Wrote the paper: WL TDQ.

References

  1. 1. Başkaya MK, Muralikrishna Rao A, Doğan A, Donaldson D, Dempsey RJ (1997) The biphasic opening of the blood–brain barrier in the cortex and hippocampus after traumatic brain injury in rats. Neuroscience Letters 226:33–36.
  2. 2. Chodobski A, Zink BJ, Szmydynger-Chodobska J (2011) Blood–brain barrier pathophysiology in traumatic brain injury. Translational stroke research 2:492–516.
  3. 3. Neuwelt E, Abbott NJ, Abrey L, Banks WA, Blakley B, et al. (2008) Strategies to advance translational research into brain barriers. The Lancet Neurology 7:84–96.
  4. 4. Shlosberg D, Benifla M, Kaufer D, Friedman A (2010) Blood–brain barrier breakdown as a therapeutic target in traumatic brain injury. Nature Reviews Neurology 6:393–403.
  5. 5. Adelson PD, Whalen M, Kochanek P, Robichaud P, Carlos T (1998) Blood brain barrier permeability and acute inflammation in two models of traumatic brain injury in the immature rat: a preliminary report. Acta Neurochirurgica Supplement 71 104–106.
  6. 6. Dempsey RJ, Baskaya MK, Dogan A (2000) Attenuation of brain edema, blood-brain barrier breakdown, and injury volume by ifenprodil, a polyamine-site N-methyl-D-aspartate receptor antagonist, after experimental traumatic brain injury in rats. Neurosurgery 47:399–406.
  7. 7. Tofts PS (2010) T1-weighted DCE imaging concepts: modelling, acquisition and analysis. signal 500:400.
  8. 8. Leach MO, Brindle K, Evelhoch J, Griffiths JR, Horsman MR, et al. (2005) The assessment of antiangiogenic and antivascular therapies in early-stage clinical trials using magnetic resonance imaging: issues and recommendations. British journal of cancer 92:1599–1610.
  9. 9. Ding G, Jiang Q, Li L, Zhang L, Zhang ZG, et al. (2008) Angiogenesis Detected After Embolic Stroke in Rat Brain Using Magnetic Resonance T2*WI. Stroke 39:1563–1568.
  10. 10. Durukan A, Marinkovic I, Strbian D, Pitkonen M, Pedrono E, et al. (2009) Post-ischemic blood–brain barrier leakage in rats: One-week follow-up by MRI. Brain Research 1280:158–165.
  11. 11. Ewing JR, Knight RA, Nagaraja TN, Yee JS, Nagesh V, et al. (2003) Patlak plots of Gd-DTPA MRI data yield blood–brain transfer constants concordant with those of 14C-sucrose in areas of blood–brain opening. Magnetic Resonance in Medicine 50:283–292.
  12. 12. Wei XE, Wang D, Li MH, Zhang YZ, Li YH, et al. (2011) A Useful Tool for the Initial Assessment of Blood–Brain Barrier Permeability After Traumatic Brain Injury in Rabbits: Dynamic Contrast-Enhanced Magnetic Resonance Imaging. Journal of Trauma and Acute Care Surgery 71:1645–1651.
  13. 13. Wei XE, Zhang YZ, Li YH, Li MH, Li WB (2012) Dynamics of rabbit brain edema in focal lesion and perilesion area after traumatic brain injury: a MRI study. Journal of neurotrauma 29:2413–2420.
  14. 14. Nagaraja TN, Karki K, Ewing JR, Divine GW, Fenstermacher JD, et al. (2010) The MRI-measured arterial input function resulting from a bolus injection of Gd-DTPA in a rat model of stroke slightly underestimates that of Gd-[14C]DTPA and marginally overestimates the blood-to-brain influx rate constant determined by Patlak plots. Magnetic Resonance in Medicine 63:1502–1509.
  15. 15. Ewing JR, Bagher-Ebadian H (2013) Model selection in measures of vascular parameters using dynamic contrast-enhanced MRI: experimental and clinical applications. NMR in Biomedicine 26:1028–1041.
  16. 16. Talley Watts L, Long JA, Chemello J, Van Koughnet S, Fernandez A, et al. (2014) Methylene Blue Is Neuroprotective against Mild Traumatic Brain Injury. Journal of Neurotrauma 31:1063–1071.
  17. 17. Long JA, Watts LT, Chemello J, Huang S, Shen Q, et al.. (2014) Multiparametric and longitudinal MRI characterization of mild Traumatic Brain Injury in rats. Journal of neurotrauma. doi:doi:https://doi.org/10.1089/neu.2014.3563..
  18. 18. Jiang Z, Chen CH, Chen YY, Han JY, Riley J, et al. (2014) Autophagic effect of programmed cell death 5 (PDCD5) after focal cerebral ischemic reperfusion injury in rats. Neuroscience Letters 566:298–303.
  19. 19. Gürsoy-Özdemir Y, Bolay H, Saribaş O, Dalkara T (2000) Role of Endothelial Nitric Oxide Generation and Peroxynitrite Formation in Reperfusion Injury After Focal Cerebral Ischemia. Stroke 31:1974–1981.
  20. 20. Yankeelov TE, Cron GO, Addison CL, Wallace JC, Wilkins RC, et al. (2007) Comparison of a reference region model with direct measurement of an AIF in the analysis of DCE-MRI data. Magnetic Resonance in Medicine 57:353–361.
  21. 21. Pike M, Stoops C, Langford C, Akella N, Nabors L, et al. (2009) High-resolution longitudinal assessment of flow and permeability in mouse glioma vasculature: Sequential small molecule and SPIO dynamic contrast agent MRI. Magnetic Resonance in Medicine 61:615–625.
  22. 22. Ewing JR, Brown SL, Lu M, Panda S, Ding G, et al. (2005) Model selection in magnetic resonance imaging measurements of vascular permeability: Gadomer in a 9L model of rat cerebral tumor. Journal of Cerebral Blood Flow & Metabolism 26:310–320.
  23. 23. Pike MM, Stoops CN, Langford CP, Akella NS, Nabors LB, et al. (2009) High-resolution longitudinal assessment of flow and permeability in mouse glioma vasculature: Sequential small molecule and SPIO dynamic contrast agent MRI. Magnetic Resonance in Medicine 61:615–625.
  24. 24. Aryal MP, Nagaraja TN, Keenan KA, Bagher-Ebadian H, Panda S, et al. (2014) Dynamic contrast enhanced MRI parameters and tumor cellularity in a rat model of cerebral glioma at 7 T. Magnetic Resonance in Medicine. 71:2206–2214.
  25. 25. Duong TQ (2007) Cerebral blood flow and BOLD fMRI responses to hypoxia in awake and anesthetized rats. Brain Research 1135:186–194.
  26. 26. Shen Q, Ren H, Fisher M, Bouley J, Duong TQ (2004) Dynamic tracking of acute ischemic tissue fates using improved unsupervised ISODATA analysis of high-resolution quantitative perfusion and diffusion data. Journal of Cerebral Blood Flow & Metabolism 24:887–897.
  27. 27. Shen Q, Fisher M, Sotak CH, Duong TQ (2004) Effects of Reperfusion on ADC and CBF Pixel-by-Pixel Dynamics in Stroke: Characterizing Tissue Fates using Quantitative Diffusion and Perfusion Imaging. Journal of Cerebral Blood Flow & Metabolism 24:280–290.