Carbonation Test Study on Low Calcium Fly Ash Concrete

Article Preview

Abstract:

Making full use of fly ash (FA) is an important part of sustainable materials development in the word. This paper discussed the carbonation resistance of concrete with 10%, 20% and 25% fly ash replacement ratios(FA%). The process was accelerated in artificial carbonation laboratory by controlling 20% concentration of CO2, 10°C~30°C temperature and 50%~70% relative humidity(RH). The depth of carbonation could be observed by spraying phenolphthalein solution on the fresh broken concrete surface. The test results show that adding fly ash into concrete results in the decrease of cement consumption and calcium hydroxide, so carbonation rate increases. But with the increase of FA% and carbonization time, the drop speed of carbonation rate slower, the differences in the microstructure are detailed. In addition, the carbonation rate increases when the ambient temperature varies from 10°C to 30°C and ambient RH falls from 70% to 50%. It concludes that the 10°C ambient temperature and 70% ambient RH are superior to other environmental conditions for enhanceing concrete carbonation resistance, and mixing 10%~25% FA into concrete have little influence on carbonation resistance of concrete if have adequate curing time.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

327-331

Citation:

Online since:

October 2010

Export:

Price:

[1] J. Khunthongkeaw and S. Tangtermsirikul. Model for Simulating Carbonation of Fly Ash Concrete. American Society of Civil Engineers, Journal of Materials In Civil Engineering, Vol. 9-10 (2005), p.570.

DOI: 10.1061/(asce)0899-1561(2005)17:5(570)

Google Scholar

[2] P.F. Marques and A. Costa. Service life of RC structures: Carbonation induced corrosion. Prescriptive vs. performance-based methodologies. Construction and Building Mateials, Vol. 24 (2010), pp.258-265.

DOI: 10.1016/j.conbuildmat.2009.08.039

Google Scholar

[3] J.K. Kim, C.Y. Kim, S.T. Yi and Y. Lee. Effect of carbonation on the rebound number and compressive strength of concrete. Cement & Concrete Composites, Vol. 31 (2009), pp.139-144.

DOI: 10.1016/j.cemconcomp.2008.10.001

Google Scholar

[4] Y. Chen and T. W. Study on steel corrosion amount before concrete corrosion cracking induced by carbonation. Concrete, Vol. 12 (2005), pp.63-66.

Google Scholar

[5] H. Al-Khaiat and N. Fattuhi. Carbonation of Concrete Exposed to Hot and Arid Climate. American Society of Civil Engineers, Journal of materials in civl engineering, Vol. 3-4 (2002), pp.97-107.

DOI: 10.1061/(asce)0899-1561(2002)14:2(97)

Google Scholar

[6] P. Sulapha, S.F. Wong, T.H. Wee and S. Swaddiwudhipong. Carbonation of Concrete Containing Mineral admixtures. American Society of Civil Engineers, Journal of materials in civl engineering, Vol. 3-4 (2003), pp.134-142.

DOI: 10.1061/(asce)0899-1561(2003)15:2(134)

Google Scholar

[7] H.W. Song, S.J. Kwon, K.J. Byun and C.K. Park. Predicting carbonation in early-aged cracked concrete. Cement and Concrete Research, Vol. 36 (2006). pp.979-989.

DOI: 10.1016/j.cemconres.2005.12.019

Google Scholar

[8] K. Sisomphon and L.F. Thomas. Carbonation rates of concretes containing high volume of pozzolanic materials. Cement and Concrete Research, Vol. 37 (2007), pp.1647-1653.

DOI: 10.1016/j.cemconres.2007.08.014

Google Scholar

[9] C.D. Atis. Accelerated carbonation and testing of concrete made with fly ash. Construction and Building Materials, Vol. 17 (2003), pp.147-152.

DOI: 10.1016/s0950-0618(02)00116-2

Google Scholar

[10] C.D. Atis. Carbonation-Porosity -Strength Model for Fly Ash Concrete. American Society of Civil Engineers, Journal of materials in civl engineering. Vol. 1-2 (2004), pp.91-94.

DOI: 10.1061/(asce)0899-1561(2004)16:1(91)

Google Scholar

[11] G. Li. Climatic conditions impact on the carbonation rate of concrete. Conrete, Vol. 11 (2004), pp.49-51.

Google Scholar