An Airflow Analysis Study of Quadrotor Based Flying Sniffer Robot

Article Preview

Abstract:

Wheeled based sniffer robots have been using in current research trend of odor plume tracking, but they have a serious pitfall because they only perform2D odor plume tracking which is ineffective. The main reason of being ineffective is because wheeled sniffer robots ignore the fact that the majority of odor plumes are released into 3D space instead of 2D space. Therefore, a flying sniffer robot is needed to overcome 3D odor plume tracking problem. In this paper, we propose to use a quadrotor as the locomotion of a flying sniffer robot. In order to make sure the quadrotor based flying sniffer robot can perform well in odor plumes tracking, we have carried out a detail study in airflow simulation analysis by using Computational Fluid Dynamics (CFD) software. Besides, we also conducted experiments to determine the odor sensing ability of quadrotor based flying sniffer robot. From our experiments, we are able to identify the odor sensing region of quadrotor based flying sniffer robot in quantitative measurement. From airflow analysis simulation study and experiments, we proved that a quadrotor based flying sniffer robot is a feasible solution for 3D odor plume tracking.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

246-250

Citation:

Online since:

September 2014

Export:

Price:

* - Corresponding Author

[1] K. Lindsey, 7 Things You Don't know about Moths, OurAmazingPlanet Contributor. [Online]. Available: http: /www. livescience. com/21933-moth-week-facts. html. [Accessed: 22-Mar-2014].

Google Scholar

[2] M. E. Cablk, J. C. Sagebiel, J. S. Heaton, and C. Valentin, Olfaction-based Detection Distance: A Quantitative Analysis of How Far Away Dogs Recognize Tortoise Odor and Follow It to Source, MDPI Sensors, vol. 8, no. 4, p.2208–2222, (2008).

DOI: 10.3390/s8042208

Google Scholar

[3] H. Ishida, Y. Wada, and H. Matsukura, Chemical Sensing in Robotic Applications: A Review, IEEE Sens. J., vol. 12, no. 11, p.3163–3173, Nov. (2012).

DOI: 10.1109/jsen.2012.2208740

Google Scholar

[4] W. Jatmiko, F. Jovan, R. Y. S. Dhiemas, A. M. Sakti, F. M. Ivan, and A. Febrian, Robots Implementation For Odor Source Localization Using PSO Algorithm, WSEAS Trans. Circuits Syst., vol. 10, no. 4, p.115–125, (2011).

Google Scholar

[5] L. Osório, G. Cabrita, and L. Marques, Mobile Robot Odor Plume Tracking Using Three Dimensional Information, in European Conference on Mobile Robots, 2011, p.1–6.

Google Scholar

[6] H. Ishida, Blimp robot for three-dimensional gas distribution mapping in indoor environment, in Proceedings of the 13th International Symposium on Olfaction and Electronic Nose. AIP Conference Proceedings, 2009, vol. 1137, no. 1, p.61–64.

DOI: 10.1063/1.3156627

Google Scholar

[7] W. Riddle, Dutch Police Add Pot-Sniffing Helicopter to Drug War Arsenal., [Online]. Available: http: /www. switched. com/2009/05/05/dutch-police-add-pot-sniffing-helicopter-to-drug-war-arsenal/. [Accessed: 22-Mar-2014].

Google Scholar

[8] L. L. López, Moth-Like Chemo-Source Localisation and Classification on an Indoor Autonomous Robot, On Biomimetics, p.453–466, (2005).

Google Scholar

[9] R. A. Russell, A. Bab-Hadiashar, R. L. Shepherd, and G. G. Wallace, A comparison of reactive robot chemotaxis algorithms, Rob. Auton. Syst., vol. 45, no. 2, p.83–97, Nov. (2003).

DOI: 10.1016/s0921-8890(03)00120-9

Google Scholar

[10] F. van Breugel and M. H. Dickinson, Plume-tracking behavior of flying Drosophila emerges from a set of distinct sensory-motor reflexes, Curr. Biol., vol. 24, no. 3, p.274–86, Feb. (2014).

DOI: 10.1016/j.cub.2013.12.023

Google Scholar