A Renewable C Reactive Protein Amperometric Immunosensor Based on Magnetic Multiwalled Carbon Nanotubes Probles Modified Electrode

Article Preview

Abstract:

A disposable, magnetism-controlled, and amperometric immunosensor was fabricated for the determination of C reactive protein (CRP). Firstly, Fe3O4 (core)/Au (shell) nanoparticle (GMP)–coated multiwalled carbon nanotubes (MWCNT–GMP) were prepared. Then, monoclonal antibody (anti-CRP) was immobilized on MWCNT–GMP to prepare MWCNT–GMP/anti-CRP composite magnetic probes. At last, the probes was adsorbed on the surface of N,N''-bis-(2-hydroxy-methylene)-o-phenylenediamine cobalt (CoRb) modified, screen-printed carbon electrodes through external magnetic field.The amount of CRP in the serum sample was determined by one-step immunoassay. When different concentrations of CRP were added into25μL of phosphate-buffered solution (pH7.0) containing10-4M H2O2, the percentage of DPV cathodic peak current decrease (CR%) exhibited a linear relationship with the concentration of CRP in the range of 0.3–100 μg L-1.The detection limit was 0.16 μg L-1(3б).The immunosensor was used to determine CRP in serum samples of patients with heart diseases, and the results were consistent with those of the traditional ELISA method. The proposed amperometric immunosensor was sensitive, rapid, magnetic field–controlled, and disposable; therefore, it could be used to determine even traces of CRP in the blood serums of patients with heart diseases.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

452-456

Citation:

Online since:

July 2011

Export:

Price:

[1] Priscila V C, Patricia T C, Assuero F G ed, Heterologous expression, characterization and structural studies of a hydrophobic peptide from the HIV-1 p.24 protein,J. Peptides 26(2005) 243-249.

Google Scholar

[2] C.C. Lee A.I. Adler M.S. Sandhu et al . Association of C-reactive protein with type 2 diabetes: prospective analysis and meta-analysis,J. Diabetologia 52(2009) 1040-1047.

DOI: 10.1007/s00125-009-1338-3

Google Scholar

[3] Sonia C, Laura B S, Sara T, Detection of C Reactive Protein(CRP) in Serum by an Electrochemical Aptamer-Based Sandwich Assay,J. Electroanalysis. 21(2009)1309-1315.

DOI: 10.1002/elan.200804560

Google Scholar

[4] Perez-Filgueir D M, Brayfield B P, Phiri S, ed. Preserved antigenicity of HIV-1 p.24 produced and purified in high yields from plants inoculated with a tobacco mosaic virus (TMV)-derived vector,J. Virological. Methods. 121(2004)201-208.

DOI: 10.1016/j.jviromet.2004.06.022

Google Scholar

[5] Jongwon P, Shigeru K, Junji W. Evaluation of 2-Methacryloyloxyethyl Phosphorylcholine Polymeric Nanoparticle for Immunoassay of C-Reactive Protein Detection, JAnal. Chem. 76(2004)2649-2655.

DOI: 10.1021/ac035321i

Google Scholar

[6] Gan N, Li T H, Lei J P, ed. Electrochemical Immunosensor for Human Immunodeficiency Virus p.24 Antigen Based on Mercapto Succinic Acid Hydrazide Copper Monolayer Modified Gold Electrode Chin,J. Anal. Chem. 36(2008)1167-1171.

DOI: 10.1016/s1872-2040(08)60064-x

Google Scholar

[7] Li S X, Li J Z, Xie J Q, ed. Studies om Schiff Base Complexes Containing Cu(Ⅱ) Used as Mimetic Peroxidase,J. Chin. Acta. Chimica. Sinica. 62(2004)567-572.

Google Scholar

[8] Xu Q, Mao C, Liu N N, ed. Direct electrochemistry of horseradish peroxidase based on biocompatible carboxymethyl chitosan-gold nanoparticle nanocomposite Biosens,J. Bioelectron. 22(2006)768-774.

DOI: 10.1016/j.bios.2006.02.010

Google Scholar

[9] Min L G, Yuan R, Cai Y Q, ed. An Immunosensor for Carcinoembryonic Antigen Based on Gold Nanoparticles and Multi-wall Carbon Nanotube-Pt-chitosan Composite Chin,J. Acta. Chimica. Sinica. 66(2008)1676-1680.

Google Scholar

[10] Orla D, Kieran W, Kevin K, ed. Quantitative detection of C-reactive protein using phosphocholine-labelled enzyme or microspheres,J. Analytical Bioc. 312(2003)175-181.

DOI: 10.1016/s0003-2697(02)00439-6

Google Scholar

[11] Debra R R. Zeolite-Modified E and Electrode-Modified Z ,J. Chem. Rev. 90(1990)867-878.

Google Scholar