[1]
Linea guida per la identificazione, la qualificazione e il controllo di accettazione di compositi fibrorinforzati a matrice inorganica (FRCM) da utilizzarsi per il consolidamento strutturale di costruzioni esistenti (in italian), Consiglio Superiore dei Lavori Pubblici, (2018).
DOI: 10.3280/pm2013-016009
Google Scholar
[2]
F.G. Carozzi, A. Bellini, T. D'Antino et al, Experimental investigation of tensile and bond properties of Carbon-FRCM composites for strengthening masonry elements, Compos. Part B 128 (2017) 110-119.
DOI: 10.1016/j.compositesb.2017.06.018
Google Scholar
[3]
A. Bellini, M. Bovo, C. Mazzotti, Experimental and numerical evaluation of fiber-matrix interface behaviour of different FRCM systems, Compos. Part B 161 (2019) 411-426.
DOI: 10.1016/j.compositesb.2018.12.115
Google Scholar
[4]
F. Parisi, I. Iovinella, A. Balsamo, N. Augenti, A. Prota, In-plane behaviour of tuff masonry strengthened with inorganic matrix–grid composites, Compos. Part B 45 (2013) 1657–1666.
DOI: 10.1016/j.compositesb.2012.09.068
Google Scholar
[5]
C. Calderini, S. Cattari, S. Lagomarsino, The use of the diagonal compression test to identify the shear mechanical parameters of masonry, Constr. Build. Mater. 24 (2010) 677-685.
DOI: 10.1016/j.conbuildmat.2009.11.001
Google Scholar
[6]
F. Ferretti, A. Incerti, B. Ferracuti, C. Mazzotti, FRCM strengthened masonry panels: the role of mechanical anchorages and symmetric layouts, Key Eng. Mat. 747 (2017) 334-341.
DOI: 10.4028/www.scientific.net/kem.747.334
Google Scholar
[7]
A. Incerti, A.R. Tilocca, F. Ferretti, C. Mazzotti, Influence of masonry texture on the shear strength of FRCM reinforced panels, in: RILEM Bookseries, Vol 18. (2019) Springer, Cham, 1623–1631.
DOI: 10.1007/978-3-319-99441-3_174
Google Scholar
[8]
A. Bellini, A. Incerti, M. Bovo, C. Mazzotti, Effectiveness of FRCM reinforcement applied to masonry walls subject to axial force and out-of-plane loads evaluated by experimental and numerical studies, Int. J. Archit. Herit., 12(3) (2018) 376-394.
DOI: 10.1080/15583058.2017.1323246
Google Scholar
[9]
S. Babaeidarabad, F. De Caso, A. Nanni, Out-of-plane behavior of URM walls strengthened with Fabric-Reinforced Cementitious Matrix Composite, J. Compos. Constr.,18(4),.
Google Scholar
[10]
N. Gattesco, C. Amadio, S. Barelli, C. Bedon, G. Rinaldin, F. Zorzini, Analisi ciclica di pareti murarie in pietrame rinforzate mediante intonaco armato con rete in GFRP. In: XV Convegno L'Ingegneria Sismica in Italia, ANIDIS, Padova, (2013).
Google Scholar
[11]
N. Gattesco, I. Boem, Experimental and analytical study to evaluate the effectiveness of an in-plane reinforcement for masonry walls using GFRP meshes, Constr. Build. Mater. 88 (2015) 94-104.
DOI: 10.1016/j.conbuildmat.2015.04.014
Google Scholar
[12]
A. Incerti, A. Vasiliu, B. Ferracuti, C. Mazzotti, Uniaxial compressive tests on masonry columns confined by FRP and FRCM, in: 12th Int. Symp. Fiber Reinf. Polym. Reinf. Concr. Struct. 5th Asia-Pacific Conf. Fiber Reinf. Polym. Struct. Jt. Conf. Nanjing, China, (2015).
Google Scholar
[13]
EN 772-1. Methods of test for masonry units – Part 1: Determination of compressive strength. (2015).
Google Scholar
[14]
EN 1015-11. Methods of test for mortar for masonry – Part 11: Determination of flexural and compressive strength of hardened mortar. (2007).
DOI: 10.3403/01905442u
Google Scholar
[15]
ASTM E519-15. Standard test method for diagonal tension (shear) in masonry assemblages. American Society for Testing Material, (2015).
Google Scholar
[16]
M.M. Frocht, Recent advances in photoelasticity. ASME Trans, 55, 135-153, (1931).
Google Scholar